08 67 13 Roof Opening Protection Systems
PART 1 GENERAL
- SECTION INCLUDES
- CageGuard Skylight Protector.
- SkyDome Skylight Protector.
- ScreenGuard Skylight Protector.
- SkyGuard Skylight Protector.
- HatchProtector Roof Hatch Safety System.
- REFERENCES
- OSHA 29 CFR 1926.502(b).
- OSHA 29 CFR 1910.23(a) Occupational Health and Safety Standards for General Industry, Subpart Guarding floor and wall openings and holes.
- OSHA 29 CFR 1910.29 – Occupational Health and Safety Standards for General Industry, Subpart Manually propelled mobile ladder stands and scaffolds (towers).
- SUBMITTALS
- Submit under provisions of Section 01 30 00.
- Product Data: Manufacturer’s data sheets on each product to be used, including:
- Preparation instructions and recommendations.
- Storage and handling requirements and recommendations.
- Installation methods.
- Shop Drawings: Complete details of entire railing layout, showing member sizes and part identification, fasteners, anchors, fittings and evidence of compliance with structural performance requirements.
- QUALITY ASSURANCE
- Manufacturer Qualifications: Minimum of 15 years experience manufacturing portable railing systems.
- Installer Qualifications: Minimum 2 person crew capable of positioning base plates and installing portable railing systems according to manufacturers instructions.
- DELIVERY, STORAGE, AND HANDLING
- Store products in manufacturer’s unopened packaging until ready for installation.
PART 2 PRODUCTS
- MANUFACTURERS
- Provide products as manufactured by Garlock Safety Systems, Plymouth, MN, garlocksafety.com, Email: sales@garlockequip.com
- Requests for substitutions will be considered in accordance with provisions of Section 01 60 00.
- PERFORMANCE REQUIREMENTS
- Structural Performance: Comply with requirements of applicable local, state, and federal codes.
- Structural performance of top rails and supports:
- Capable of withstanding a concentrated load of 200 pounds (90.6 kg), applied to the top rail at any point and in any direction.
- Capable of withstanding a uniform load of 50 pounds per linear foot (74.3 kg/m) applied to the top rail horizontally with a simultaneous load of 100 pounds per linear foot (148.6 kg/m) applied vertically downward.
- Design need not provide for both concentrated and uniform loads to be applied concurrently.
- Structural performance of railing infill:
- Capable of withstanding a horizontal concentrated load of 200 pounds (90.6 kg), applied to one foot (30.5mm) square area at any point on the infill.
- Infill includes panels, intermediate rails, posts and other elements.
- Design need not provide for infill loads to be applied concurrently with top rail loading.
- Horizontal members not to exceed 12 inch (305 mm) spacing over lens area of skylight.
- EQUIPMENT
- CageGuard Skylight Protector: Free-standing, non-penetrating design clamps on two diagonal corners of opening. Can also be mechanically attached.
- Meets OSHA 1910.23(a)(4) and 1926.501(b)(4).
- Rail: 1-5/8 inch (41 mm) O.D. by 0.065 inch (2.7 mm) wall HREW tubing. Tubing epoxy powder coated safety yellow.
- Base: Free standing non-penetrating steel plate base with adjustable tubing extension, Base and tube are galvanized steel, epoxy powder coated safety yellow.
- Slip-on Stack Plate weights. Provide each base with __ plates per base.
- Free standing non-penetrating RailGuard 90 lb base. Base is galvanized steel epoxy powder coated safety yellow.
- Size (Height/Width/Length):
- __ inch (___ mm) by __ inch (___ mm) by __ inch (___ mm).
- SkyDome: Temporary non-penetrating skylight protection system.
- Meets OSHA 1910.23(a)(4) and 1926.501(b)(4).
- Material:
- Tubing: 1-5/8 inch (41 mm) O.D. by 0.065 inch (2.7 mm) wall HREW tubing.
- Mesh Cover: Galvanized steel welded wire mesh welded to frame.
- Provide with Hurricane tether.
- Finish: [Epoxy powder coated safety yellow] [Epoxy powder coated color as selected by Architect].
- Size (Overall Height/Base Width/Base Length/Curb Height):
- 20 inch (508 mm) / 41 inch (1441 mm) / 41 inch (1441 mm) / 10 inch (254 mm)
- 9 inch (229 mm) / 30 inch (762 mm) / 54 inch (1372 mm) / 2 inch (51 mm)
- 15 inch (381 mm) / 33 inch (838 mm) / 56 inch (1422 mm) / 7 inch (178 mm)
- 23 inch (584 mm) / 36 inch (914 mm) / 36 inch (914 mm) / 11 inch (279 mm)
- 12 inch (305 mm) / 41 inch (1441 mm) / 41 inch (1441 mm) / 2 inch (51 mm)
- 19 inch (483 mm) / 44 inch (1118 mm) / 44 inch (1118 mm) / 8 inch (203 mm)
- 25 inch (635 mm) / 48 inch (1219 mm) / 48 inch (1219 mm) / 10 inch (254 mm)
- 28 inch (711 mm) / 48 inch (1219 mm) / 109 inch (2769 mm) / 16 inch (406 mm)
- 33 inch (838 mm)/ 52 inch (1321 mm) / 90 inch (2286 mm) / 20 inch (508)
- 31 inch (787 mm) / 54 inch (1372 mm)/ 54 inch (1372 mm) / 16 inch (406 mm)
- 23 inch (584 mm) / 55 inch (1397 mm) / 92 inch (2337 mm) / 9 inch (229 mm)
- 29 inch (737 mm) / 55 inch (1397 mm) / 97 inch (2464 mm) / 16 inch (406 mm)
- 25 inch (635 mm) / 56 inch (1422 mm) / 76 inch (1930 mm) / 11 inch (279 mm)
- 19 inch (483 mm) / 57 inch (1748 mm) / 57 inch (1748 mm) / 5 inch (127 mm)
- 23 inch (584 mm) / 58 inch (1473 mm) / 104 inch (2642 mm) / 9 inch (229 mm)
- 28 inch (711 mm)/ 59 inch (1499 mm) / 127 inch (3226 mm) / 13 inch (330 mm)
- 29 inch (737 mm) / 60 inch (1524 mm) / 60 inch (1524 mm) / 11 inch (279 mm)
- 25 inch (635 mm) / 60 inch (1524 mm) / 103 inch (2616 mm) / 10 inch (254 mm)
- 30 inch (762 mm) / 64 inch (1626 mm) / 109 inch (2769 mm) / 14 inch (356 mm)
- 30 inch (762 mm) / 64 inch (1626 mm / 113 inch (2870 mm) / 14 inch (356 mm)
- 28 inch (711 mm)/ 69 inch (1753 mm) / 81 inch (2057 mm) / 11 inch (279 mm)
- 29 inch (737 mm) / 74 inch (1880 mm) / 119 inch (3023 mm) / 10 inch (254 mm)
- 35 inch (889 mm) / 84 inch (2134 mm) / 84 inch (2134 mm) / 14 inch (356 mm)
- 34 inch (864 mm) / 90 inch (2286 mm) / 90 inch (2286 mm) / 12 inch (305 mm)
- Custom sizes as indicated on the Drawings.
- ScreenGuard: Compression fit, non-penetrating galvanized screen secures to skylight frame.
- Meets OSHA Requirements: 1910.23(a) (4) and 1926.501 (b) (4).
- Galvanized sheet steel base frame covered with galvanized expanded steel mesh screen.
- Size (Overall Dome Height / Width / Length):
- 7 inch (178 mm) / 24 inch (610 mm) / 24 inch (610 mm).
- 8 inch (203 mm) / 28 inch (711 mm / 28 inch (711 mm).
- 8 inch (203 mm) / 28 inch (711 mm / 52 inch (1321 mm).
- 10 inch (254 mm) / 36 inch (914 mm) / 36 inch (914 mm).
- 10 inch (254 mm) / 36 inch (914 mm) / 52 inch (1321 mm).
- 10 inch (254 mm) / 42 inch (1067 mm) / 76 inch (1930 mm).
- 12 inch (305 mm) / 42 inch (1067 mm) / 42 inch (1067 mm).
- 12 inch (305 mm) / 42 inch (1067 mm) / 80 inch (2032 mm).
- 14 inch (356 mm) / 52 inch (1829 mm) / 52 inch (1829 mm).
- 14 inch (356 mm) / 52 inch (1829 mm) / 76 inch (1930 mm).
- 14 inch (356 mm) / 52 inch (1829 mm) / 96 inch (2438 mm).
- Custom sizes as indicated on the Drawings.
- Load Rating:
- 24 inch (610 mm) / 24 inch (610 mm) – 500 lbs.
- 24 inch (610 mm) / 36 inch (914 mm) – 500 lbs.
- 36 inch (914 mm) / 36 inch (914 mm) – 500 lbs.
- 36 inch (914 mm) / 48 inch (1219 mm) – 500 lbs.
- 48 inch (1219 mm) / 48 inch (1219 mm) – 500 lbs.
- 48 inch (1219 mm / 60 inches (1524 mm) – 500 lbs.
- 48 inch (1219 mm / 72 inches (1829 mm) – 500 lbs.
- 48 inch (1219 mm / 94 inches (2398 mm) – 500 lbs.
- 48 inch (1219 mm / 96 inches (2438 mm) – 440 lbs.
- SkyGuard: Free-standing, modular skylight and hatch protection system.
- Meets OSHA Requirements: 1910.23(a) (4) and 1926.501(b) (4)
- Material:
- Frame: Galvanized steel corner frame with wide base and rubber foot pads.
- Tubing: 1-5/8 inch (41 mm) O.D. by 0.065 inch (2.7 mm) wall HREW galvanized tubing.
- Tubing epoxy powder coated safety yellow.
- Size (Length / Width / Height): Lower rail height is 20 inches (508 mm).
- 54 inch (1372 mm) / 54 inch (1372 mm) / 42 inch (1067 mm).
- 102 inch (2591 mm) / 54 inch (1372 mm) / 42 inch (1067 mm).
- 102 inch (2591 mm) / 102 inch (2591 mm) / 42 inch (1067 mm).
- Custom sizes as indicated on the Drawings.
- HatchProtector: Adjustable compression fit design mounts directly to the roof hatch, non-penetrating.
- Meets OSHA Requirements: 1910.23(a) (4) and 1926.501(b) (4).
- Frame: Galvanized steel corner frame and base.
- Rails: Telescoping 1-5/8-inch (41mm) O.D. by 0.065 in. (2.7 mm) wall HREW galvanized tubing for outer tubes.
- Self-closing steel gate
- Top rail height: 42 in.
- Mid rail height: 20 in.
- Grab Bars: [Mini stairway- 1 or 2 required] [Deluxe Stairway- 1 or 2 required] [Ladder- 2 required]
- Size: [30 in. by 36 in.] 36 in. by 36 in.] [30 in. by 54 in.] [30 in. by 96 in.] [36 in. by 54 in.] [36 in. by 96 in.] [42 in. by 42 in.] [48 in. by 48 in.] [48 in. by 60 in.] [Custom sizes as indicated on drawings].
- Finish: [galvanized] [Epoxy powder coated safety yellow] [Epoxy powder coated color as selected by Architect].
- CageGuard Skylight Protector: Free-standing, non-penetrating design clamps on two diagonal corners of opening. Can also be mechanically attached.
PART 3 EXECUTION
- EXAMINATION
- Do not begin installation until substrates have been properly prepared.
- If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
- PREPARATION
- Clean surfaces thoroughly prior to installation.
- Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.
- INSTALLATION
- Install in accordance with manufacturer’s instructions.
- Before installation, inspect all parts to insure no damaged parts are used.
- Secure CageGuard Skylight Protector to the base with securing pins.
- PROTECTION
- Protect installed products until completion of project.
- Touch-up, repair or replace damaged products before Substantial Completion.